5 Parameter description
5.1 Direct Dialling – Memories
Parameter
Value Description Default Exam.1 Exam.2
1 t nn… No. nn under button t
- - -
t – Button number (memory) [1-4]
nn – telephone number up to 16 digits to be stored.
Refer to the table for other choices.
The number stored in parameter 1 is the number for the
first group or the number for Day mode.
Parameter
Value Description Default Exam.1 Exam.2
2 t nn… No. nn under button t
- - -
t – Button number (memory) [1-4]
nn – telephone number up to 16 digits to be stored.
Refer to the table for other choices.
The number stored in parameter 2 is the number for the
second group or the number for Night mode
Note: The switchover to Day/Night mode remains set in the
unit even after line disconnection.
5.2 Relay
Parameter
Value Description Default Exam.1 Exam.2
31 m
Relay mode
1 1 2
m – relay mode [ 1-2]
m=1 relay mode – relay will close on command or password for ss period
(used for electrical locks, gate opening, etc.)
m=2 button mode – (activated by button press e.g. external bell).
parameter
dial
0 - 9 0 - 9
# #
* **
Recall * #
Pause * 0
parameter
choice
0 - 9 0 - 9
# #
* **
Recall * #
Pause * 0
Comentarios a estos manuales