Parameter
Value Description Default Exam.1
Exam.2
44 xxxx
Password
0000 0000 0000
xxxx – service password for entry to programming
Parameter
Value Description Default Exam.1
Exam.2
45 dd
DAY MODE switching
11 11 11
46 nn
NIGHT MODE switching
10 10 10
dd – command for DAY MODE switching [2 digits]
nn – command for NIGHT MODE switching [2 digits]
Note: The switchover to Day/Night mode remains set in unit even after line
disconnection.
Parameter
Value Description Default Exam.1
Exam.2
47 e
Dialling mode
1 1 0
e – operating mode of unit
e=0 selects 2-Group mode, e=1 selects Day/Night mode.
5.4 Time parameters
Parameter
Value Description Default Exam.1
Exam.2
51 q
Number of rings before
pick-up
2 1 2
q – Number of incoming call rings before a call is picked up. The number can
be set from 1 to 9.
Parameter Value Description Default Exam.1
Exam.2
52 d
Maximum call duration
2 1 4
d – maximum time in minutes for which a call may last.
This time can be extended during a call by dialling
Prolong Call digit from telephone (*or #). Time
setting is per table.
time
[min]
choice
0,5 0
1 - 9 1 - 9
15 *
30 #
Comentarios a estos manuales